Gates with one or two side packings model COMPRESS DOOR II with zinc-coated lower guiding system buried in the floor and sub-divided in 52 mm complex thick insulated leaves.

Leaves made of internal perimetral sash of tubular of 50x50x2, zinc-coated and covered on both sides with zinc-coated metal sheet 0,7/0,8 mm thick, pre-painted in Isotek standard colors (White-grey similar with RAL 7035, other colors upon request), protection of the surface with semi-adherent film to be removed after installing (care of the installer after the pose); internal insulating material 50 mm thick fire-proof class 1 (extruded polystyrene - Styrofoam), density 35 kg/m3.

The opening is made with black SMC hinges that join the leaves with double resistance ball bearing and axel of 20 mm in diameter, some of them with closing ball bearing with PVC piston fixed in the floor.

Between two leaves there are anti-crushing EPDM rubber gaskets, that cover a 50 mm width, according to the norms, an optimal closing without the passage of air is ensured.

On the upper and lower side, the leaves have a black aluminum profile, on which a 40 mm air-proof nylon brush is inserted.

All the gates have carrying upper guiding system with zinc-coated profile painted basic BLACK with 3-rolled nylon bearings (for SINGLE-LEAF gates with 4 leaves, a 4-rolled carrying upper guiding system is used).

The sustaining of the gate is made with side mullions of zinc-coated rectangular profile, painted black.

The blocking of the leaves is made with an internal closing system completed with blocking rods (also for the motorized gates) ready for the insertion of a pulling handle, 50 mm spacing corks inserted in the lower side of the leaf during the installation.

NB: We recommend the insertion of an angle profile of 40x40x2 mm rectangular and zinc-coated in the floor (hollow space width + side packings ? pillars). It must be perpendicular to the lower brush at 45 mm from the maximum obstacle that covers the side of the installation, in order to create a leaning floor with 10 mm in the exterior to allow the water draining. The floor in the leaves? moving area has to be flat and straight. Otherwise, we don?t guarantee the perfect waterproof protection and the light-free space between the brushes and the floor.

Gate weight: approx. 30 Kg. / m2 invoicable.